Volume 2, No. 3
Special section: Non-linear Analysis of Concrete Structures edited by Prof.
T. Ueda
Snapback Failure Analysis for Large Scale Concrete
Structures and its Application to Shear Capacity Study of Columns (Invited paper)
Tada-aki Tanabe, Atsushi Itoh and Naoshi Ueda
Journal of Advanced Concrete Technology, 2(3) 275-288, 2004
A comprehensive failure analysis method for large-scale
concrete structures is presented, which includes snap-back failure. Energy observation
is used to describe the macroscopic mechanism of snapback occurrences and other softening
failure modes.
The typical snapback failures of beams and columns by shear are numerically obtained
using the arc length method with selected displacement control points. The fundamental
understanding of the phenomena is extended to the failure mechanism of a column where
shear capacity is affected by axial force.
Crack Shear-Slip in Reinforced Concrete Elements
Frank J. Vecchio and Derek Lai
Journal of Advanced Concrete Technology, 2(3) 289-300, 2004
A calculation procedure is described for estimating crack
shear stresses and crack slip displacements from average strain measurements made
on reinforced concrete panels. Several series of panels, previously tested, are examined
and crack shear-slip data are extracted. These data are compared against the predictions
of previously developed crack slip models, as well as against an alternative constitutive
model proposed herein. Reasonable correlation is found between experi-mental and
calculated values, particularly at near-ultimate load conditions. It is then shown
that including crack shear slip behaviour in a computational model results in improved
accuracy in terms of predicted load-deformation response and ultimate load capacity
for reinforced concrete elements such as panels, beams and shear walls. Further,
it is shown that rigorously accounting for crack slip displacements results in a
better representation of various subtle aspects of behaviour, such as the failure
mode and the capacity of elements to deform and redistribute load.
Time-Dependent Post-Peak Softening of RC Members
in Flexure
Khaled Farouk El-Kashif and Koichi Maekawa
Journal of Advanced Concrete Technology, 2(3) 301-315, 2004
To investigate the rate effects on post-peak structural
behavior accompanying the compression softening of structural concrete, experimental
studies were carried out on over-reinforced concrete beams with and without confinement
under varied rates of flexural loading. The effects of loading rate on the capacity
and ductility of RC beams were found more pronounced in confined cases than unconfined
cases. The generic time-dependent constitutive model of compression-softened concrete
was applied to nonlinear collapse analysis and its applicability was verified by
experiments. The strain rate in the compressive localized zone in structures rapidly
increased after the member reached its peak capacity even though the rate of displacement
was kept unchanged especially in the case of unconfined beams. In the case of confined
RC beams, localization of weak strain occurred but with comparatively greater time-dependent
plasticity and fracturing within the structure. These deformation characteristics
were adequately simulated by nonlinear analysis using a time-dependent constitutive
model for softened concrete in compression.
Analysis of FRP-Strengthened RC Members with Varied
Sheet Bond Stress-Slip Models
HuneBum Ko and Yuichi Sato
Journal of Advanced Concrete Technology, 2(3) 317-326, 2004
Finite element analysis was conducted for ten RC specimens,
which were shear-strengthened with fiber-reinforced polymer (FRP) sheets. Four of
the ten specimens were wrapped with unbonded sheets to observe influence of the bond
to the strengthening effectiveness. The tests and analyses demonstrated that the
unbonded sheets are not effective to increase the shear strength of a member without
steel stirrups while the flexural ductility of a member can be improved by confinement
with unbonded sheets. Parametric calculations were attempted with varied interfacial
fracture energy Gf and maximum bond stress y between the sheet and concrete. The
calculations indicated that the Gf and the y have limited influence on the shear
strength while the local stresses and crack widths can be controlled to a certain
extent.
Diagonal Tensile Failure Mechanism of Reinforced
Concrete Beam
Yasuhiko Sato, Toshiya Tadokoro and Tamon Ueda
Journal of Advanced Concrete Technology, 2(3) 327-341, 2004
The mechanism of diagonal tensile failure of RC beams without
shear reinforcement, which is difficult to solve by means of experimental and analytical
study, is investigated. The close relationship between the fracture modes and the
transfer stress at shear cracks is clarified, and the experimental results are verified
by the finite element method taking into consideration the influence of a splitting
tensile crack and dowel action. In RC members without shear reinforcement, the width
of a shear crack increases owing to the occurrence of a splitting tensile crack along
the main bars. As a result, the transfer stress of a shear crack cannot be generated
and the shear crack grows and propagates rapidly. This paper also puts forth that
FE analysis, in which not only shear crack but also splitting tensile crack are modeled
discretely, can predict the size effect on diagonal tensile failure strength of RC
beams without shear reinforcement.
Nonlinear Analysis of RC Structural Members Using
3D Lattice Model
Tomohiro Miki and Junichiro Niwa
Journal of Advanced Concrete Technology, 2(3) 343-358, 2004
This study attempts to expand the application of the conventional
2D lattice model, which can express the shear resisting mechanism of RC structural
members, to a 3D analytical model. Use of a 3D lattice model for the simulation of
torsional and biaxial responses of RC structural members is presented. The results
of static analysis are compared with several sets of experimental results for RC
beams/columns subjected to pure torsion or cyclic combined loads of torsion and bending.
In addition, the dynamic analysis of RC columns subjected to bilateral seismic loading
is carried out. The applicability of 3D lattice model to the response prediction
of RC structural members under 3D loading is examined by comparing analytical and
experimental results.
Mesoscopic Simulation of Failure of Mortar and
Concrete by 2D RBSM
Kohei Nagai, Yasuhiko Sato and Tamon Ueda
Journal of Advanced Concrete Technology, 2(3) 359-374, 2004
Concrete is a heterogeneous material consisting of mortar
and aggregate at the meso level. Evaluation of the fracture process at this level
is useful to clarify the material characteristic of concrete. However, the analytical
approach at this level has not yet been sufficiently investigated. In this study,
two-dimensional analyses of mortar and concrete are car-ried out using the Rigid
Body Spring Model (RBSM). For the simulation of concrete, constitutive model at the
meso scale are developed. Analysis simulates well the failure behavior and the compressive
and tensile strength relationship of mortar and concrete under uniaxial and biaxial
stress conditions. Localized compressive failure of concrete is also simulated qualitatively.[PDF: 2.2MB]
Assessment of Damage Level for Low-Rise RC Buildings
Based on Seismic Capacity Index (Is)
Manabu Yoshimura, Takaya Nakamura and Katsumi Yagi
Journal of Advanced Concrete Technology, 2(3) 375-383, 2004
In Japan, the seismic performance of existing RC buildings
is evaluated by computing the seismic capacity index, Is, using the Standard for
Seismic Evaluation of Existing RC Buildings, while the damage level of RC buildings
that undergo earthquakes is assessed by the Standard for Post-Earthquake Inspection
and Guidelines for Repair and Strengthening Technology. This paper reports the results
of investigation of the relation between the Is value and the damage level for low-rise
RC buildings designed according to the old code by conducting dynamic analysis on
model buildings with a variety of Is values. The effects of the deformability type
of columns and the number of stories on the relation between the Is value and the
damage level were studied. Two levels of ground motions, the original level of past
earthquake records and the design standard level, were considered. In the analysis,
column hysteresis was derived from test results. Strength deterioration after shear
failure and axial collapse that are commonly associated with hysteretic behavior
of old columns, were considered. The method presented in this study enables assessment
of the damage level of buildings and the damage condition of columns if the deformability
type of columns, number of stories, Is value and ground motion are given. In addition,
the assessed damage level of buildings are compared with the observed damage level
from past earthquakes and the Is value required to prevent collapse of buildings
is discussed.
Criterion for Preventing Formation of
Story Mechanism in Vertically Irregular Wall Buildings
Thuat V. Dinh and Toshikatsu Ichinose
Journal of Advanced Concrete Technology, 2(3) 385-394, 2004
Wall buildings with vertically irregular configurations
have been severely damaged or even collapsed due to the forma-tion of a story mechanism
during severe earthquakes, particularly under near-fault earthquake excitation. This
paper presents a criterion to prevent such failures. A story-safety factor is defined
to represent the relative reserve strength against a story mechanism in the structure.
The validity of this factor was examined by conducting dynamic response analyses
of various analytical models of 7- and 11-story wall structures with discontinuous
wall panels in the first story using 29 real earthquake records (mostly near-fault
records) and their scaled motions with various intensity levels. The results show
that the proposed story-safety factor controlled well the failure mechanism of the
structures. When the story-safety factor was larger than the corresponding dynamic
shear magnification factor (Paulay and Priestley 1992) minus unity, a story mechanism
did not occur in the structures in all cases. A practical procedure for using the
story-safety factor to prevent the formation of a story mechanism in irregular stories
is also presented.
Experimental Study on Stress-Strain Curve of Concrete
Considering Localized Failure in Compression
Ken Watanabe, Junichiro Niwa, Hiroshi Yokota and Mitsuyasu Iwanami
Journal of Advanced Concrete Technology, 2(3) 395-407, 2004
One of the important factors for compressive stress-strain
curves of concrete is the localization of failure. The stress-strain curve of concrete
strongly depends on the aspect ratio of the concrete specimen; therefore, a unique
stress-strain curve is not adequate to express the softening behavior of concrete.
To overcome the problem related to the localization of failure, a series of uniaxial
compressive tests of concrete specimens was conducted. From the measured energy distribution,
the failed specimen was assumed to be composed of 2 or 3 zones. Then, an equation
for an envelope curve involving a characteristic of compressive strength of concrete
was formulated so as to match the experimental curve of each zone. Combining 2 or
3 proposed equations considering the extent of each zone could express the experimental
stress-strain curve of the specimen regardless of the aspect ratio.
Development of a Light Weight Reactive Powder
Concrete
Abouzar Sadrekarimi
Journal of Advanced Concrete Technology, 2(3) 409-417, 2004
Reactive Powder Concrete (RPC) is an ultra-high-strength,
high ductility and low porosity cementitious material. RPC properties are improved
by pressing fresh RPC samples, which can increase its specific weight as high as
3000 kg/m3. However, high specific weight may be a shortcoming, where weight saving
is important. Following to this review, a set of tests on RPC samples with high silica
fume contents were carried out in a laboratory. The results show that although high
silica fume content increases the compressive strength, however it decreases the
density. It is concluded that by means of silica fume it is possible to produce high
strength RPC with a specific weight as low as 1900 kg/m3. This Light Weight Reactive
Powder Concrete (LWRPC) could be used in areas where substantial weight savings can
be realized and where some of the remarkable characteristics of the material can
be fully utilized.
Prevention of Peeling Failure in Plated Beams
Hossam El-Dim M. Sallam, Abd-Allah M. Saba, Hamdy H. Shahin and Houssein
Abdel-Raouf
Journal of Advanced Concrete Technology, 2(3) 419-429, 2004
Peeling failure is one of the main drawbacks of reinforced
concrete (RC) members strengthened by externally bonded plates. Two different techniques
are suggested to prevent peeling failure at the ends of steel plates glued to the
soffits of RC beams. In the first technique, concrete cover is replaced by grout
to enhance the resistance of substrate to crack initiation and propagation. In the
second technique, permanent compressive forces at the ends of bonded plate are applied
using different plate end anchorage systems, i.e. end anchorage by bolts or by clamps.
Furthermore, two different sizes of side plates, with and without end anchorage,
are glued to the plated beam to delay or prevent the peeling failure. An analytical
model is suggested to predict the load-deflection behavior of beams strengthened
by bonded steel plates at the bottom and sides of the beams. The results of 4PB tests
indicate that conventional plated beam (PB) experience reduction in ductility and
limited enhancement in ultimate load, which increased only by 22% compared to unplated
beams due to the occurrence of peeling failure. Peeling failure of plated beams can
be prevented through the use of either a concrete cover replacement technique or
bolted anchorage systems. Anchorage of a side plated beam increased the ultimate
load by 264% compared to an unplated beam and 217% compared to PB.
Interaction of Pre-Induced Damages along
Main Reinforcement and Diagonal Shear in RC Members
Kukrit Toongoenthong and Koichi Maekawa
Journal of Advanced Concrete Technology, 2(3) 431-443, 2004
The mechanical interaction of pre-induced damage and diagonal
shear was investigated with regard to corrosion cracks in concrete and rupture of
the web reinforcement along the main reinforcement. First, localized corrosion cracking
was produced in concrete around the mid-span of beams in both compression and tension
fibers, and a mechanical interaction was no longer identified. Next, cracking occurred
near the beam supports inside a shear span and around the anchorage zones of longitudinal
steel. A diagonal shear crack was observed to meet the pre-existing cracking around
the anchorage zones of longitudinal steel. Crack propagation into the anchorage zones
resulted in significant decline in the overall capacity. On the other hand, the overall
capacity could be maintained or even increased by keeping anchorage failure from
occurring. Finally, RC beams with artificial defects in both concrete and web reinforcement
over the whole shear span were tested. Damage around anchorage zones was concluded
to play a critical role in triggering shear sliding failure in pre-damaged reinforced
concrete. |
-
|